Furnace Transformer Pump
Furnace Transformer Pump

Furnace Transformer Pump

MOQ : 1 Piece

Furnace Transformer Pump Specification

  • Caliber
  • 25 mm
  • Inlet/Outlet
  • 1 inch / 1 inch
  • Max Suction
  • 6 meter
  • Theory
  • Centrifugal Pump
  • Mounting Type
  • Foot Mounted
  • Features
  • Compact Design, Corrosion Resistance, High Temperature Operation
  • Discharge Pressure
  • 2 bar
  • Flow Rate
  • 40 L/min
  • Frequency
  • 50 Hz
  • Control System
  • Manual / Automatic
  • Head Size
  • 18 meter
  • Speed
  • 2800 RPM
  • Noise Level
  • 75 dB
  • Material
  • Cast Iron / Stainless Steel
  • Structure
  • Single Stage
  • Power
  • 0.75 kW (1 HP)
  • Standard
  • IS 8472
  • Fuel Type
  • Oil / Diesel
  • Pressure
  • Up to 2.5 bar
  • Suction Type
  • Single Suction
  • Seals Type
  • Mechanical Seal
  • Priming
  • Self Priming
  • Capacity
  • 2400 L/hour
 

Furnace Transformer Pump Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Main Export Market(s)
  • North America, Eastern Europe, Western Europe, Central America, South America
  • Main Domestic Market
  • All India
 

About Furnace Transformer Pump

With rich industry knowledge and experience, we are able to manufacture, export and supply a wide range of Furnace Transformer Pump. Due to its high efficiency and smooth functioning, the provided pump is used in diverse industries for various applications. Designed with perfection, offered pump is also rigorously checked for set quality parameters to ensure its flawless working. As per the varied demands of clients, the Furnace Transformer Pump is available in various capacities at most reasonable prices.

Features:

  • Easy installation

  • Sturdiness

  • Low maintenance

  • Long working life

CENTRIFUGAL

Model

Motor HP

Discharge in LPM

Total Head in Mt.

Suction

Delivery

1120

2.0

112 to 385

15 to 4.6

38

38

1130

3.0

112 to 430

18 to 4.2

38

38

1143

4.3

750 to 1200

11 to 7.5

100

100

1175

7.5

830 to 2250

20 to 7.5

150

150


AXIAL FLOW (IN-LINE)

Model

Motor HP

Discharge in LPM

Total Head in Mt

Suction

Delivery

1205

0.5 HP 1 PH

300/350

2.5

80

80

0.5 HP 3 PH

1220

2.0

1800

2.5

200

200

1000

0.83

1585

0.8

833

1.12

1230

3.0

1200

3.35

150

150

1250

5.0

2700

2.5

200

200

3400

3.0

200

200

4500

3.0

200

200




Durable and Efficient Design

Crafted from cast iron and stainless steel, this furnace transformer pump delivers reliable operation in demanding environments. Its compact structure and corrosion-resistant materials make it suitable for continuous high-temperature applications while ensuring longevity and low maintenance.


Advanced Priming and Sealing Technology

This pump features a self-priming mechanism, eliminating the need for manual intervention during startup. The mechanical seal enhances system integrity, preventing leaks and supporting safe operation with oil or diesel fuels, making it ideal for industrial furnace systems.

FAQs of Furnace Transformer Pump:


Q: How does the centrifugal theory benefit the performance of the Furnace Transformer Pump?

A: The centrifugal theory ensures efficient fluid movement by converting rotational energy from the motor into kinetic energy, resulting in a steady, high flow rate of up to 40 L/min and a head of 18 meters, ideal for rapid oil or diesel transfer processes.

Q: What maintenance steps are required to ensure the mechanical seal remains effective?

A: Routine inspection and cleaning of the mechanical seal, along with checking for wear or leakage, are crucial. Use compatible oil or diesel fuels, and follow manufacturer guidelines to maximize seal longevity and maintain a leak-free, secure pumping environment.

Q: When should you use the self-priming feature during operation?

A: Utilize the self-priming feature whenever the pump needs to draw fluid from a lower level or after installation, cleaning, or maintenance. This function ensures quick and hassle-free startup without manual filling or air evacuation, enhancing operational convenience.

Q: Where is the ideal installation point for this pump?

A: The pump should be foot-mounted on a stable, level surface, close to the fluid source. Its compact design allows integration into industrial systems such as furnace fuel supply lines, ensuring efficient transfer and easy access for servicing.

Q: What process does the single-stage design follow for liquid transfer?

A: The single-stage design means the pump uses a single impeller to move fluid, optimizing energy consumption and simplifying the flow path. This leads to consistent discharge pressure, efficient operation at 2 bar, and straightforward maintenance.

Q: How does corrosion resistance benefit pump applications with oil or diesel?

A: Corrosion-resistant materials like cast iron and stainless steel are key for preventing surface degradation, even when handling aggressive or high-temperature fuels. This extends pump lifespan, reduces downtime, and ensures reliable, safe performance.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Transformer Oil Pumps Category

Advanced Transformer Oil Pump

Advanced Transformer Oil Pump

Minimum Order Quantity : 1 Piece

Theory : Centrifugal Pump

Voltage : 220380V

Mounting Type : Base Mounted

Fuel Type : Other, Electric

Rectifier Transformer Pump

Rectifier Transformer Pump

Minimum Order Quantity : 1 Piece

Theory : Electromagnetic Pump

Voltage : 415 V

Mounting Type : Horizontal

Fuel Type : Other, Electric

Cast Iron Transformer Oil Pump

Cast Iron Transformer Oil Pump

Price 2000 INR / Piece

Minimum Order Quantity : 1 Piece

Theory : Rotary pump theory, Other

Voltage : 220V/380V

Mounting Type : Basemounted

Fuel Type : Other, Electric

Oil Pump Distribution Tran

Oil Pump Distribution Tran

Minimum Order Quantity : 1 Piece

Theory : Rotary Pump

Voltage : 220V

Mounting Type : Horizontal

Fuel Type : Other, Diesel, Lubricating Oil



Back to top